0426 459 273

Safety switch installation

RCD installation and switchboard protection across the St George area and the Sutherland Shire — the device that protects people rather than wiring.

Close view of an open switchboard with breakers and RCD devices
An open board. If nothing in here has a test button, there is no safety switch protection.

A fuse and a safety switch do different jobs

This is the part most people have never been told. A fuse or a circuit breaker protects the wiring — it cuts the power when a circuit draws more current than the cable can carry, so the cable does not overheat.

A safety switch, properly an RCD, protects the person. It watches the current going out and the current coming back, and if some of it is going somewhere it should not — through a person, through water, through a damaged cable — it cuts the supply in about thirty milliseconds.

A board full of fuses and no RCD will happily let someone be electrocuted without tripping. That is not a worst case, it is how fuses work.

How to tell what you have

Open your switchboard and look for a device with a small TEST button on it. That is an RCD. No test button anywhere means you have no safety switch protection at all.

Plenty of homes have one covering only part of the house — commonly the power points but not the lights, or the original circuits but not an added extension. Partial coverage is very common and most owners assume they are fully protected.

Test it every three months

Press the test button. The power should cut immediately. Switch it back on.

If it does not trip, the device has failed and needs replacing — an RCD that does not trip is just an expensive switch. Mark it in your calendar quarterly; it takes ten seconds.

What the standard requires

Under AS/NZS 3000, new and altered circuits require RCD protection. That means any work we do brings the affected circuits up to standard, and it is often the point at which an older board runs out of room and needs replacing.

Older installations that have not been touched are not retrospectively illegal, but that is a technicality rather than a reason to leave them.

When it keeps tripping

A safety switch that trips repeatedly is not faulty and is not being fussy. It is detecting current leaking to earth, and something is causing that.

The usual culprits are a failing appliance, moisture in an outdoor circuit — very common around here after rain, particularly closer to the water — or degraded insulation on an old cable. We isolate which circuit and which appliance rather than replacing the RCD and hoping.

Where we work

We install safety switches across Blakehurst, Carss Park, Connells Point, Kyle Bay, Oatley, Hurstville and Kogarah, and throughout the Sutherland Shire including Sylvania, Caringbah, Miranda, Sutherland and Cronulla.

Call 0426 459 273 Open 24 hours